Semiconductor Equipment Refurbishment

FAST offer full remanufacture, upgrade and refurbishment of legacy obsolete CO2 Wafer Cleaning Platforms – namely the WC1600, WC2100 and WC2100Ex models.

FAST Wafer Cleaning removes particulate contamination, post-etch veils and fences, as well as thin-film organic residues from Silicon, Compound, MEMS and MR Head wafers using a unique carbon dioxide (CO2) snow cleaning process. FAST Wafer Cleaning is a fast, environmentally friendly, “all dry” non-contact process that offers numerous advantages over conventional wet cleaning systems.

Features 

  • Stand-alone automated system
  • Environmentally controlled Class 1 cleaning chamber
  • Cassette-to-cassette handling
  • User friendly flat panel touch screen colour display
  • Wafer temperature control
  • Internal dew point monitor
  • Compact footprint
  • Advanced ESD control
  • GEM/SECS-II software
  • Simple facilitization
  • CE Marked, Semi S2, S8 compliant

Benefits

  • Superior cleaning performance
  • Reduced cycle times
  • No chemical waste
  • Non-damaging clean of fragile structures
  • High PRE down to nano particle size
  • High thruput due to short cycle time
  • High MTBF, low MTTR

Options

  • GEM/SECS-II software
  • Advanced ESD Control
  • Wafer pre aligner
  • CO2 supply integration
  • Rear service FPD touch screen
  • Bar code scanner
  • Wafer cassette scanner
  • Uninterruptable power supply
  • On-site spares kit
  • Wafer Edge Clean
Semiconductor Equipment Refurbishment FAST Technologies Chemtech wafer clean

Specification

Performance

Thruput: up to 60 wafers per hour

Wafers:

  • 3” to 8” Round [75mm to 200 mm]
  • 8” x 8” Square [200 mm x 200 mm]

 

Semiconductor Equipment Refurbishment FAST Technologies Chemtech wafer clean

Facilities Requirements

Power: 200-240V AC, 13 A, 50/60Hz, I phase

Carbon Dioxide:

  • Grade 5 Bulk or Cylinders
  • 2 SCFM [56 SLPM]
  • 70 psi [5 bar] CDA or N2
Semiconductor Equipment Refurbishment FAST Technologies Chemtech wafer clean

PI Gas (option):

  • 6 SCFM [170 SLPM]
  • 100 psi [7 bar] CDA or N2

Pneumatic Gas:

  • 0.5 SCFM [14 SLPM]
  • 85 psi [6 bar] CDA or N2

Exhaust:

  • Peak Usage – 7 SCFM [198 SLPM]
  • Nominal Usage – 2 SCFM [56 SLPM]
  • Connector – 2 x 2” round duct

Start your automation journey. Get in touch.

    Select your area of interest*